home > products & services > water meters > SmartFlow Mobile™ > technical
| Scope | Item | Detail |
|---|---|---|
| Features | Pipe Sizes | Yes |
| Measuring Principle | Yes | |
| Velocity Range | Yes | |
| Configuration | Yes | |
| Accuracy | Velocity 0-2 m/s | DN 13-50: 0.05 m/s DN 50-300: 0.02 m/s DN 300-6000: 0.01 m/s |
| Velocity 2-32 m/s | DN 13-50: 2.5% DN 50-300: 1% relative to Q DN 300-6000:1.5% relative to Q |
|
| Temperature | Operating Temp | -20°C to +55°C |
| Water Temp | -40°C to +80°C | |
| Display | Format | 16 letters LCD, with 9 digits for actual flow |
| Data read out | Flow Rate, velocity, totalised volume for forward or reverse | |
| External Mounting | Straps | FLW120 (ArtNo# 414243) |
| IP | IP67 | |
| Sensor Cable Length | 10m (max 150m) | |
| Sensor Material | Plastic, Stainless Steel, Aluminium | |
| Housing | Material | Aluminium |
| Protection | IP66 | |
| Size | 170 x 142 x 75mm | |
| Output | Analogue | 4-20 mA max. Load 1kΩ |
| Pulse / Digital | 2 x Open Collector, 30 V DC / 0.1 A1 x Open Collector, 20 V DC / 1 A | |
| Input | 1 x (no volt contact) | |
| Supply Voltage | 100 to 240 V AC, 50/60 Hz or 20 to 30 V AC |